Kinesys Pinouts
MIL 10
MIL 10 | 222P | ||
---|---|---|---|
A | E-Stop 1A | 1 | |
B | E-Stop 2A | 3 | |
C | E-Stop 1B | 2 | |
D | E-Stop 2B | 4 | |
E | DMH A1 | 7, 8, 15 | |
F | DMH A2 | 9, 21 | |
G | Not connected | ||
H | 24 V | 7, 8, 15 | |
J | 0 V | 16, 22 | |
K | Not connected |
Elevation+ XLR7
Elevation+ XLR7 with ProPlex PC226T | ||
---|---|---|
1 | Data Gnd (shield) | |
2 | Data - | |
3 | Data + | |
4 | 24 V | |
5 | 0 V | |
6 | E-Stop (12 V) | |
7 | Enable (24 V) |
Elevation+ Encoder XLR6
Elevation+ Encoder XLR6 | ||
---|---|---|
1 | Data Gnd (shield) | |
2 | Data - | |
3 | ||
4 | Data - | |
5 | ||
6 | Shield, Gnd, 0 V |
Elevation+ Remote XLR5
Elevation+ Remote XLR5 | ||
---|---|---|
1 | 0 V (screen) | |
2 | Up | |
3 | Down | |
4 | 24 V | |
5 | Speed (max 5 V) |
Libra XLR4
Libra XLR4 with PC-CCT CABLE | ||
---|---|---|
1 | 0 V | |
2 | Data - | |
3 | Data + | |
4 | 24 V | |
Shell | Gnd (screen) |
Socapex 22 K2
Socapex 222P K2 | ||
---|---|---|
1 | E-Stop 1A | |
2 | E-Stop 1B | |
3 | E-Stop 2A | |
4 | E-Stop 2B | |
5 | E-Stop Trace (24 V) | |
6 | E-Stop Trace | |
7 | Start | |
8 | Drive Power Control | |
9 | Drive Enable Control | |
10 | Drives On | |
11 | Drives Enabled | |
12 | E-Stop NC Feedback | |
13 | E-Stop NC Feedback | |
14 | E-Stop Ok | |
15 | 24 V | |
16 | 0 V | |
17 | DMH 1A / Int ES 1A | |
18 | DMH 1B / Int ES 1B | |
19 | DMH 2A / Int ES 2A | |
20 | DMH 2B / Int ES 2B | |
21 | ||
22 | 0 V |
Socapex 22
Socapex 222P | |||
---|---|---|---|
1 | E-Stop 1A | E-Stop Pair 1 | |
2 | E-Stop 1B | E-Stop Pair 1 | |
3 | E-Stop 2A | E-Stop Pair 2 | |
4 | E-Stop 2B | E-Stop Pair 2 | |
5 | E-Stop Trace (24 V) | E-Stop switch normally closed - trace contact | |
6 | E-Stop Trace | E-Stop switch normally closed - trace contact | |
7 | Start | Connect to 24 V to reset E-Stop system; link to 24 V for automatic start | |
8 | Drive Power Control | Connect to 24 V to turn on line contactors | |
9 | Drive Enable Control | Connect to 24 V to enable drives | |
10 | Drives On | Line contactors signal output 24 V | |
11 | Drives Enabled | Drive enable signal output 24 V | |
12 | E-Stop NC Feedback | Linked systems only | |
13 | E-Stop NC Feedback | Linked systems only | |
14 | E-Stop Ok | E-Stop OK signal output 24 V | |
15 | 24 V | 24 V supply | |
16 | 0 V | 0 V supply | |
17 | DMH 1A / Int ES 1A | E-stop output contact 1 - linked systems only | |
18 | DMH 1B / Int ES 1B | E-stop output contact 1 - linked systems only | |
19 | DMH 2A / Int ES 2A | E-stop output contact 2 - linked systems only | |
20 | DMH 2B / Int ES 2B | E-stop output contact 2 - linked systems only | |
21 | HTR Signal | Not used | |
22 | 0 V | 0 V supply |
Socapex 22 Term
Socapex 222P Terminal Loop Back | |||||
---|---|---|---|---|---|
Pin | Description | Notes | Terminal | ||
1 | E-Stop UpLink Circuit 1 | Linked to 2 | |||
2 | E-Stop UpLink Circuit 1 | Linked to 1 | |||
3 | E-Stop UpLink Circuit 2 | Linked to 4 | |||
4 | E-Stop UpLink Circuit 2 | Linked to 3 | |||
5 | No connection | ||||
6 | E-Stop OK signal | E-Stop OK signal output 24 V | |||
7 | 24 V | 24 V supply | 14 | ||
8 | Drives On Signal | Line contactors signal output 24 V | |||
9 | 11 | ||||
10 | No connection | ||||
11 | 9 | ||||
12 | 13 | ||||
13 | 12 | ||||
14 | 7 | ||||
15 | |||||
16 | |||||
17 | 18 | ||||
18 | 17 | ||||
19 | 20 | ||||
20 | 19 | ||||
21 | |||||
22 | 0 V supply |