MIL 10
| MIL 10 | 222P | ||
|---|---|---|---|
| A | E-Stop 1A | 1 | |
| B | E-Stop 2A | 3 | |
| C | E-Stop 1B | 2 | |
| D | E-Stop 2B | 4 | |
| E | DMH A1 | 7, 8, 15 | |
| F | DMH A2 | 9, 21 | |
| G | Not connected | ||
| H | 24 V | 7, 8, 15 | |
| J | 0 V | 16, 22 | |
| K | Not connected | ||
Elevation+ XLR7
| Elevation+ XLR7 with ProPlex PC226T | ||
|---|---|---|
| 1 | Data Gnd (shield) | |
| 2 | Data - | |
| 3 | Data + | |
| 4 | 24 V | |
| 5 | 0 V | |
| 6 | E-Stop (12 V) | |
| 7 | Enable (24 V) | |
Elevation+ Encoder XLR6
| Elevation+ Encoder XLR6 | ||
|---|---|---|
| 1 | Data Gnd (shield) | |
| 2 | Data - | |
| 3 | ||
| 4 | Data - | |
| 5 | ||
| 6 | Shield, Gnd, 0 V | |
Elevation+ Remote XLR5
| Elevation+ Remote XLR5 | ||
|---|---|---|
| 1 | 0 V (screen) | |
| 2 | Up | |
| 3 | Down | |
| 4 | 24 V | |
| 5 | Speed (max 5 V) | |
Libra XLR4
| Libra XLR4 with PC-CCT CABLE | ||
|---|---|---|
| 1 | 0 V | |
| 2 | Data - | |
| 3 | Data + | |
| 4 | 24 V | |
| Shell | Gnd (screen) | |
Socapex 22
| Socapex 222P | |||
|---|---|---|---|
| 1 | E-Stop 1A | E-Stop Pair 1 | |
| 2 | E-Stop 1B | E-Stop Pair 1 | |
| 3 | E-Stop 2A | E-Stop Pair 2 | |
| 4 | E-Stop 2B | E-Stop Pair 2 | |
| 5 | E-Stop Trace (24 V) | E-Stop switch normally closed - trace contact | |
| 6 | E-Stop Trace | E-Stop switch normally closed - trace contact | |
| 7 | Start | Connect to 24 V to reset E-Stop system; link to 24 V for automatic start | |
| 8 | Drive Power Control | Connect to 24 V to turn on line contactors | |
| 9 | Drive Enable Control | Connect to 24 V to enable drives | |
| 10 | Drives On | Line contactors signal output 24 V | |
| 11 | Drives Enabled | Drive enable signal output 24 V | |
| 12 | E-Stop NC Feedback | Linked systems only | |
| 13 | E-Stop NC Feedback | Linked systems only | |
| 14 | E-Stop Ok | E-Stop OK signal output 24 V | |
| 15 | 24 V | 24 V supply | |
| 16 | 0 V | 0 V supply | |
| 17 | DMH 1A / Int ES 1A | E-stop output contact 1 - linked systems only | |
| 18 | DMH 1B / Int ES 1B | E-stop output contact 1 - linked systems only | |
| 19 | DMH 2A / Int ES 2A | E-stop output contact 2 - linked systems only | |
| 20 | DMH 2B / Int ES 2B | E-stop output contact 2 - linked systems only | |
| 21 | HTR Signal | Not used | |
| 22 | 0 V | 0 V supply | |
Socapex 22 Term
| Socapex 222P Terminal Loop Back | ||||
|---|---|---|---|---|
| Pin | Description | Notes | Terminal | |
| 1 | E-Stop UpLink Circuit 1 | Linked to 2 | ||
| 2 | E-Stop UpLink Circuit 1 | Linked to 1 | ||
| 3 | E-Stop UpLink Circuit 2 | Linked to 4 | ||
| 4 | E-Stop UpLink Circuit 2 | Linked to 3 | ||
| 5 | No connection | |||
| 6 | E-Stop OK signal | E-Stop OK signal output 24 V | ||
| 7 | 24 V | 24 V supply | 14 | |
| 8 | Drives On Signal | Line contactors signal output 24 V | ||
| 9 | Enable Control Out | Enable control loop - linked systems only | 11 | |
| 10 | No connection | |||
| 11 | Enable Control Return | Enable control loop - linked systems only | 9 | |
| 12 | Feedback Input | Feedback contact - linked systems only | 13 | |
| 13 | Feedback Input | Feedback contact - linked systems only | 12 | |
| 14 | E-Stop Trace In | Connect to 24 V via NC contact in E-Stop switch | 7 | |
| 15 | No connection | |||
| 16 | 0 V | 0 V supply | ||
| 17 | E-Stop in Circuit 1 | E-Stop switch normally closed - contact 1 | 18 | |
| 18 | E-Stop in Circuit 1 | E-Stop switch normally closed - contact 1 | 17 | |
| 19 | E-Stop in Circuit 2 | E-Stop switch normally closed - contact 2 | 20 | |
| 20 | E-Stop in Circuit 2 | E-Stop switch normally closed - contact 2 | 19 | |
| 21 | HTR Signal | Not used | ||
| 22 | 0 V | 0 V supply | ||