Kinesys Pinouts: Difference between revisions
Jump to navigation
Jump to search
m (→Socapex 22) |
|||
(2 intermediate revisions by the same user not shown) | |||
Line 277: | Line 277: | ||
= Socapex 22 = | = Socapex 22 = | ||
{| class="wikitable" style="text-align: center; | {| class="wikitable" style="text-align: center; | ||
!colspan= "3"| Socapex 222P | !colspan= "3"| Socapex 222P | ||
|- | |- | ||
Line 394: | Line 394: | ||
= Socapex 22 Term = | = Socapex 22 Term = | ||
{| class="wikitable" style="text-align: center; | {| class="wikitable" style="text-align: center; | ||
!colspan= "3"| Socapex 222P Terminal Loop Back | !colspan= "3"| Socapex 222P Terminal Loop Back | ||
|- | |||
| '''Pin''' | |||
| | |||
| '''Description''' | |||
| '''Notes''' | |||
| '''Terminal''' | |||
|- | |- | ||
! style="width: 30%"; style="color:black; background-color:yellow;" | 1 | ! style="width: 30%"; style="color:black; background-color:yellow;" | 1 | ||
! style="width: 30%"; style="color:black; background-color:yellow;" | | ! style="width: 30%"; style="color:black; background-color:yellow;" | | ||
| E-Stop UpLink Circuit 1 | |||
| Linked to 2 | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:yellow;" | 2 | ! style="color:black; background-color:yellow;" | 2 | ||
! style="color:black; background-color:black;" | | ! style="color:black; background-color:black;" | | ||
| E-Stop UpLink Circuit 1 | |||
| Linked to 1 | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:yellow;" | 3 | ! style="color:black; background-color:yellow;" | 3 | ||
! style="color:black; background-color:red;" | | ! style="color:black; background-color:red;" | | ||
| E-Stop UpLink Circuit 2 | |||
| Linked to 4 | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:yellow;" | 4 | ! style="color:black; background-color:yellow;" | 4 | ||
! style="color:black; background-color:blue;" | | ! style="color:black; background-color:blue;" | | ||
| E-Stop UpLink Circuit 2 | |||
| Linked to 3 | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 5 | ! style="color:black; background-color:;" | 5 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| No connection | |||
| | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 6 | ! style="color:black; background-color:;" | 6 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop OK signal | |||
| E-Stop OK signal output 24 V | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 7 | ! style="color:black; background-color:;" | 7 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| 24 V | |||
| 24 V supply | |||
| 14 | | 14 | ||
|- | |- | ||
! style="color:black; background-color:;" | 8 | ! style="color:black; background-color:;" | 8 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| Drives On Signal | |||
| Line contactors signal output 24 V | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 9 | ! style="color:black; background-color:;" | 9 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| Enable Control Out | |||
| Enable control loop - linked systems only | |||
| 11 | | 11 | ||
|- | |- | ||
! style="color:black; background-color:;" | 10 | ! style="color:black; background-color:;" | 10 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| No connection | |||
| | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 11 | ! style="color:black; background-color:;" | 11 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| Enable Control Return | |||
| Enable control loop - linked systems only | |||
| 9 | | 9 | ||
|- | |- | ||
! style="color:black; background-color:;" | 12 | ! style="color:black; background-color:;" | 12 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| Feedback Input | |||
| Feedback contact - linked systems only | |||
| 13 | | 13 | ||
|- | |- | ||
! style="color:black; background-color:;" | 13 | ! style="color:black; background-color:;" | 13 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| Feedback Input | |||
| Feedback contact - linked systems only | |||
| 12 | | 12 | ||
|- | |- | ||
! style="color:black; background-color:;" | 14 | ! style="color:black; background-color:;" | 14 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop Trace In | |||
| Connect to 24 V via NC contact in E-Stop switch | |||
| 7 | | 7 | ||
|- | |- | ||
! style="color:black; background-color:yellow;" | 15 | ! style="color:black; background-color:yellow;" | 15 | ||
! style="color:black; background-color:yellow;" | | ! style="color:black; background-color:yellow;" | | ||
| No connection | |||
| | |||
| | | | ||
|- | |- | ||
! style="color:lightgray; background-color:#49abF4;" | 16 | ! style="color:lightgray; background-color:#49abF4;" | 16 | ||
! style="color:black; background-color:white;" | | ! style="color:black; background-color:white;" | | ||
| 0 V | |||
| 0 V supply | |||
| | | | ||
|- | |- | ||
! style="color:black; background-color:;" | 17 | ! style="color:black; background-color:;" | 17 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop in Circuit 1 | |||
| E-Stop switch normally closed - contact 1 | |||
| 18 | | 18 | ||
|- | |- | ||
! style="color:black; background-color:;" | 18 | ! style="color:black; background-color:;" | 18 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop in Circuit 1 | |||
| E-Stop switch normally closed - contact 1 | |||
| 17 | | 17 | ||
|- | |- | ||
! style="color:black; background-color:;" | 19 | ! style="color:black; background-color:;" | 19 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop in Circuit 2 | |||
| E-Stop switch normally closed - contact 2 | |||
| 20 | | 20 | ||
|- | |- | ||
! style="color:black; background-color:;" | 20 | ! style="color:black; background-color:;" | 20 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| E-Stop in Circuit 2 | |||
| E-Stop switch normally closed - contact 2 | |||
| 19 | | 19 | ||
|- | |- | ||
! style="color:black; background-color:;" | 21 | ! style="color:black; background-color:;" | 21 | ||
! style="color:black; background-color:;" | | ! style="color:black; background-color:;" | | ||
| HTR Signal | |||
| Not used | |||
| | | | ||
|- | |- | ||
! style="color:lightgray; background-color:#49abF4;" | 22 | ! style="color:lightgray; background-color:#49abF4;" | 22 | ||
! style="color:black; background-color:white;" | | ! style="color:black; background-color:white;" | | ||
| 0 V | |||
| 0 V supply | |||
| | | | ||
|- | |- | ||
|} | |} |
Latest revision as of 23:48, 9 September 2025
MIL 10
MIL 10 | 222P | ||
---|---|---|---|
A | E-Stop 1A | 1 | |
B | E-Stop 2A | 3 | |
C | E-Stop 1B | 2 | |
D | E-Stop 2B | 4 | |
E | DMH A1 | 7, 8, 15 | |
F | DMH A2 | 9, 21 | |
G | Not connected | ||
H | 24 V | 7, 8, 15 | |
J | 0 V | 16, 22 | |
K | Not connected |
Elevation+ XLR7
Elevation+ XLR7 with ProPlex PC226T | ||
---|---|---|
1 | Data Gnd (shield) | |
2 | Data - | |
3 | Data + | |
4 | 24 V | |
5 | 0 V | |
6 | E-Stop (12 V) | |
7 | Enable (24 V) |
Elevation+ Encoder XLR6
Elevation+ Encoder XLR6 | ||
---|---|---|
1 | Data Gnd (shield) | |
2 | Data - | |
3 | ||
4 | Data - | |
5 | ||
6 | Shield, Gnd, 0 V |
Elevation+ Remote XLR5
Elevation+ Remote XLR5 | ||
---|---|---|
1 | 0 V (screen) | |
2 | Up | |
3 | Down | |
4 | 24 V | |
5 | Speed (max 5 V) |
Libra XLR4
Libra XLR4 with PC-CCT CABLE | ||
---|---|---|
1 | 0 V | |
2 | Data - | |
3 | Data + | |
4 | 24 V | |
Shell | Gnd (screen) |
Socapex 22 K2
Socapex 222P K2 | ||
---|---|---|
1 | E-Stop 1A | |
2 | E-Stop 1B | |
3 | E-Stop 2A | |
4 | E-Stop 2B | |
5 | E-Stop Trace (24 V) | |
6 | E-Stop Trace | |
7 | Start | |
8 | Drive Power Control | |
9 | Drive Enable Control | |
10 | Drives On | |
11 | Drives Enabled | |
12 | E-Stop NC Feedback | |
13 | E-Stop NC Feedback | |
14 | E-Stop Ok | |
15 | 24 V | |
16 | 0 V | |
17 | DMH 1A / Int ES 1A | |
18 | DMH 1B / Int ES 1B | |
19 | DMH 2A / Int ES 2A | |
20 | DMH 2B / Int ES 2B | |
21 | ||
22 | 0 V |
Socapex 22
Socapex 222P | |||
---|---|---|---|
1 | E-Stop 1A | E-Stop Pair 1 | |
2 | E-Stop 1B | E-Stop Pair 1 | |
3 | E-Stop 2A | E-Stop Pair 2 | |
4 | E-Stop 2B | E-Stop Pair 2 | |
5 | E-Stop Trace (24 V) | E-Stop switch normally closed - trace contact | |
6 | E-Stop Trace | E-Stop switch normally closed - trace contact | |
7 | Start | Connect to 24 V to reset E-Stop system; link to 24 V for automatic start | |
8 | Drive Power Control | Connect to 24 V to turn on line contactors | |
9 | Drive Enable Control | Connect to 24 V to enable drives | |
10 | Drives On | Line contactors signal output 24 V | |
11 | Drives Enabled | Drive enable signal output 24 V | |
12 | E-Stop NC Feedback | Linked systems only | |
13 | E-Stop NC Feedback | Linked systems only | |
14 | E-Stop Ok | E-Stop OK signal output 24 V | |
15 | 24 V | 24 V supply | |
16 | 0 V | 0 V supply | |
17 | DMH 1A / Int ES 1A | E-stop output contact 1 - linked systems only | |
18 | DMH 1B / Int ES 1B | E-stop output contact 1 - linked systems only | |
19 | DMH 2A / Int ES 2A | E-stop output contact 2 - linked systems only | |
20 | DMH 2B / Int ES 2B | E-stop output contact 2 - linked systems only | |
21 | HTR Signal | Not used | |
22 | 0 V | 0 V supply |
Socapex 22 Term
Socapex 222P Terminal Loop Back | ||||
---|---|---|---|---|
Pin | Description | Notes | Terminal | |
1 | E-Stop UpLink Circuit 1 | Linked to 2 | ||
2 | E-Stop UpLink Circuit 1 | Linked to 1 | ||
3 | E-Stop UpLink Circuit 2 | Linked to 4 | ||
4 | E-Stop UpLink Circuit 2 | Linked to 3 | ||
5 | No connection | |||
6 | E-Stop OK signal | E-Stop OK signal output 24 V | ||
7 | 24 V | 24 V supply | 14 | |
8 | Drives On Signal | Line contactors signal output 24 V | ||
9 | Enable Control Out | Enable control loop - linked systems only | 11 | |
10 | No connection | |||
11 | Enable Control Return | Enable control loop - linked systems only | 9 | |
12 | Feedback Input | Feedback contact - linked systems only | 13 | |
13 | Feedback Input | Feedback contact - linked systems only | 12 | |
14 | E-Stop Trace In | Connect to 24 V via NC contact in E-Stop switch | 7 | |
15 | No connection | |||
16 | 0 V | 0 V supply | ||
17 | E-Stop in Circuit 1 | E-Stop switch normally closed - contact 1 | 18 | |
18 | E-Stop in Circuit 1 | E-Stop switch normally closed - contact 1 | 17 | |
19 | E-Stop in Circuit 2 | E-Stop switch normally closed - contact 2 | 20 | |
20 | E-Stop in Circuit 2 | E-Stop switch normally closed - contact 2 | 19 | |
21 | HTR Signal | Not used | ||
22 | 0 V | 0 V supply |